 HIGH VOLTAGE AND HIGH VALUE RESISTORS
RESISTORS CAPACITORS COILS DELAY LINES
UHV SERIES
RoHS
Term.W is RoHS compliant & 260C compatible
Resistance values up to 200T (2x1014), tolerances to 1%! Voltage rating to 14KV. Pulse voltage to 50KV avail. Low noise & voltage coefficient Industry's best TCR, as low as 25ppm/C
World's highest resistance range!
RCD Type UHV resistors are suited for all high value applications from general purpose bleed chains to highest reliability X-ray systems and TWT amplifiers. RCD's exclusive complex oxide film features state-of-the-art performance and extended life stability. The unique molecular structure of the resistive element offers exceptional insensitivity to high voltage and thermal shock. The protective insulation provides a high dielectric voltage, and insulation resistance. Series UHV3 is hermetically sealed in a glass or ceramic case, minimizing the effects of moisture or contamination.
SPECIAL MODIFICATIONS
Screw terminations available Resistance tolerances to 0.2%, matching to 0.1% Voltage or resistance ratios up to 1000 : 11.0% Increased power, voltage, and operating frequency levels
DERATING
100
% OF RATED POWER
|1.25 [32] Min.*| |
*UHV3=1 [25.4] Min.
L
|
D

.041 [1.04] Max.
80 60 40 20 0 20 40
UHV1 & 2
RCD Type
UHV3
60 80 100 AMBIENT TEMPERATURE (C) 120 140
L (Max.) 1.102 [28.0] 1.875 [47.6] 2.00 [50.8]
RESISTANCE RANGE** 2% 1K to 100M 100 to 100M 5 to 1G 1.1G to 10G 2M to 50G 1K to 100M 100 to 100M 100K to 1G 1.1G to 50G 2M to 100G 100M to 1G 1G to 1T 1T to 10T
D .315 .040 [8.01] .315 .040 [8.01] .264 [6.7] Max.
UHV1 UHV2 UHV3
RCD TYPE
Wattage @ 25C
Working Voltage*
UHV1
1.0W
4000V
UHV2
2.0W
14,000V
UHV3
1.0W
1000V
Avail. TCR (ppm/C) 25 50 100 250 -2000 25 50 100 250 -2000 -2000 -2500 -3500
1% 1K to 100M 100 to 100M 10 to 1G 1.1G to 10G 2M to 10G 1K to 100M 100 to 100M 100K to 1G 1.1G to 50G 2M to 50G 100M to 1G 1G to 1T 1T to 5T
5% , 10% 1K to 100M 100 to 100M 5 to 1G 1.1G to 10G 2M to 100G 1K to 100M 100 to 100M 100K to 1G 1.1G to 50G 2M to 150G 100M to 1G 1G to 1T 1T to 200T
* Maximum DC or ACRMS working voltage determined by E = PR below the critical resistance value. Voltage rating is doubled in warm oil. Increased voltage ratings available. **increased range available.
PERFORMANCE CHARACTERISTICS 1
Temperature Range Voltage Coefficient 2 Insulation Resistance (500V) Load Life (1000 hours, typ.) Shelf Life (12 months, typ.) Noise (per freq. decade, typ.)
2
APPLICATION NOTES
1) Due to possible surface condensation, high voltages should not be applied in conditions of high humidity. The end caps of UHV1&2 are uninsulated and need to be mounted an adequate distance from conductors to ensure adequate isolation voltage. 2) Type UHV3 is coated with silicone to reduce condensation on the glass case and minimize shunt resistance. The coating must not be damaged or subjected to solvents; handle by terminations. UHV3 >100G are supplied with a guard band to minimize leakage current. 3) Resistance measurements on values over 1 Meg are made at 100V. 4) Resistors are available with screw terminations & tapped end caps to provide virtually any voltage or resistance value by combining in series.
UHV1&2 = -55C to +150C UHV3 = -40C to +100C 1 - 20ppm typ. UHV1 & UHV2 10 to 80ppm UHV3 1 0 13 0.5% 0.5% 2.0V/ V
1 Characteristics are typical for resistance range up to 1G , consult factory concerning higher values
Measured between 100V and 500V on values above 100M (tighter VC's available)
RESISTANCE CODE
Resistance Value
1K 1M 10M 100M 1G 10G 100G 1T 10T 100T
P/N DESIGNATION:
Scientific Notation
1x103 1x106 1x107 1x108 1x109 1x1010 1x1011 1x1012 1x1013 1x1014
Resis. Code 1% 2%-10%
1001 1004 1005 1006 1G00 10G0 100G 1T00 10T0 100T 102 105 106 107 1G0 10G 100G 1T0 10T 100T
UHV3
- 1T50 - F B 101 W
RCD Type Option Codes assigned by RCD (leave blank if std) Resis. Code 1% Tol: 3 signif. figures & multiplier (1001=1K, 1004= 1M, 1006=100M, 1G00= 1G, 1T50 =1.5T, etc.) Resis. Code 2% - 10%: 2 signif. figures & multiplier (105= 1M, 107=100M, 1G5= 1.5G, 15T=15T). Refer to Resis. Code table Tolerance Code: K=10%, J=5%, G=2%, F=1% Packaging: B =Bulk, T= Tape & Reel Temp. Coefficient (PPM/C): 25=25ppm, 50=50ppm, 101=100ppm, 102=1000ppm, 202=2000ppm, 252=2500ppm, 352=3500ppm Termination: W= Lead-free, Q= Tin/Lead (leave blank if either is acceptable)
RCD Components Inc, 520 E.Industrial Park Dr, Manchester, NH, USA 03109 rcdcomponents.com Tel: 603-669-0054 Fax: 603-669-5455 Email:sales@rcdcomponents.com
FA061B Sale of this product is in accordance with GF-061. Specifications subject to change without notice.
72


▲Up To Search▲   

 
Price & Availability of UHV3-105-FB

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X